CT Scan Machines

department-1

CT/E single

2.0MHU Anode heat capacity

500kHU/min max anode dissipation rate

500kHU/min max anode dissipation rate

On-board 24 KW Generator

120 cm metal-free scannable range

Supports 180kg patients accurately

65cm aperture

± 20 degree gantry tilt

department-1

CT/E Dual

2.0MHU Anode heat capacity

500kHU/min max anode dissipation rate

500kHU/min max anode dissipation rate

On-board 24 KW Generator

120 cm metal-free scannable range

Supports 180kg patients accurately

65cm aperture

± 20 degree gantry tilt

department-1

Hi-Speed Single

3.5 MHU anode heat capacity

820 KHU/min max anode dissipation rate

On-Board 24KW Generator

134 cm metal-free scannable range.

Supports 205 kg (450lbs) patients accurately

70cm aperture

± 30 degree gantry tilt

department-1

Hi-Speed NXI Dual

3.5 MHU anode heat capacity

820 KHU/min max anode dissipation rate

On-Board 24KW Generator

134 cm metal-free scannable range.

Supports 205 kg (450lbs) patients accurately

70cm aperture

± 30 degree gantry tilt

department-1

Lightspeed 4/8/16

440 mA capability

53kW generator

High Frequency High Voltage Generator

6.3 MHU X-ray Tube

Controls on Front and Back of Gantry

In-room start

Remote Gantry Tilt

205 kg (450 lb) maximum allowed with normal operation

department-1

Bright Speed 4/8/16

440 mA capability

53kW generator

High Frequency High Voltage Generator

6.3 MHU X-ray Tube

Controls on Front and Back of Gantry

In-room start

Remote Gantry Tilt

205 kg (450 lb) maximum allowed with normal operation

department-1

VCT

Aperture: 70cm

Tilt: ± 30 Degree

8 MHU x-ray tube

Heat Dissipation:

Anode (max)> 2100KHU/min

Casing (cont) 648 KHU/min

Table Load Capacity : 227 kb (500lb) Maximum Allowed

With ± .25mm positianal accuracy

Mammography Machines

department-1

Senographe 700t/800t

High Frequency X-Ray Generator Delivering Constant Voltage.

Exposure Modes – Three Exposure Modes

Automatic Optimization of Parameters. (AOP) - Fully Automatic, AEC – Semi Automatic and manual) offer the Ultimate Flexibility and ease of Use. Compact designee

department-1

Senographe DMR+

Dual Track Molybdenum/Rhodium X-RayTube

Exclusive Technological Advantages to Improve Image Quality, reduce Exposure Time and lessen X-Ray Exposure Time.

0.01mm and 0.03mm FocalSpot Sizes provide high Spatial resolution and excellent Image Contrast.

department-1

Senographe digital

GE exclusive Molybdenum / Rhodium dual track tube

Automatic Optimization of Parameters (AOP) automatically selects all exposure parameters based on breast radiological properties, for all breast sizes and types

Three AOP modes enable more flexibility in dose management

• Improved conspicuity with Fine View processing

Seamless digital workflow connectivity